Existing: Hub151 http://people.ucsc.edu/~warner/jim2/Mainstage-MDF.jpg in the MainStage building feeds 100 Mb/s fiber to the Experimental Theater (7923) hub303. Working fiber to the Expt Theater is 62 micron multimode. Four station cables installed with the building construction in 1996 are Category 5 wire. They connect the closet and the Theater control booth and perhaps points beyond. The entire building is served through two conduits from the cable closet. We have pictures from both ends: http://people.ucsc.edu/~warner/jim2/Exp-Thtr-booth-3.jpg http://people.ucsc.edu/~warner/jim2/ducts-1.jpg.JPG The location of the closet and the control room are shown on the plan: http://people.ucsc.edu/~warner/jim2/Exp-Thtr-proposal.PNG The WTC report contemplates replacing the local switch with an 8 port 10/100 Cisco unit. It expects to recable the facility and to add two WAPs. The report projects a project cost of $7000 closet remodel + 2880 rewire + 1641 switch + 2940 wireless. Total = $14,461. It appears that the connector plates on the side walls have conduits back to the theater booth. See: http://people.ucsc.edu/~warner/jim2/Exp-Thtr-data-plate-1.jpg These plates have some audio cables, but probably some empty conduits, too. NextG installed a 24 strand singlemode cable between the mainstage bldg and the experimental theater. Three strands are in use. The SM fiber is spliced through to the roof in the Expt-Theater closet. See: http://people.ucsc.edu/~warner/jim2/exp-thtr-closet-wall.jpg The Expt-Theater closet has an exterior door on a mechanical master key. ITS does not have keys to the theater itself. Proposed: 1. Replace hub303 with Gig-E switch. 2. Provide Gig-E feed to Experimental Theater (7923). Least expensive may be to use SM from Music and the gig-E over MM to experimental theater, converted with a switch. 3. Install new equipment rack in the closet. 4. Replace all existing cables with category 6 cable terminated in the rack. Conduits appear to exist to all locations on the proposed plan. If cables are not pulled for wi-fi at the same time, it may be necessary to repull all the wire when it is added. ==== Side walls to the theater form rated exit corridors and should not be penetrated.